Classroom · Medical imaging
NMR and MRI physics
Spins, relaxation, echoes, k-space and pulse sequences, simulated with the Bloch equations.
40 lessons, text and equations; animations coming soon.
Early edition: these lessons are being reviewed.
Introductory level (12)
- Larmor precession of spins in B0A magnetic moment with angular momentum placed in a static magnetic field B₀ does not simply align with the field.
- T1 recovery (longitudinal)T1 recovery describes how longitudinal magnetization regrows toward its equilibrium value M₀ after a radiofrequency pulse disturbs it.
- T2 decay (transverse)T2 decay is the loss of transverse magnetization after an RF pulse, as the spins that were precessing together drift out of phase.
- FID to spectrum with the Fourier transformAfter a radiofrequency pulse, the transverse magnetization precesses and decays, inducing a signal called the free induction decay (FID) in the receiver coil.
- Chemical shift and shieldingIn NMR, nuclei in different electronic environments resonate at slightly different frequencies because electrons shield the nucleus from the applied magnetic field.
- Sampling, Nyquist and aliasingDigital signals in NMR and MRI are measured at discrete time points.
- RF pulse and flip angleA radiofrequency (RF) pulse oscillating at the Larmor frequency tips the net magnetization away from the main field direction.
- Boltzmann spin polarizationIn a magnetic field, nuclear spins such as hydrogen protons split into a lower-energy and a higher-energy state.
- Slice selection with gradientsIn MRI, a magnetic field gradient makes the Larmor frequency vary linearly with position along one axis.
- How to read a pulse-sequence diagram (RF, gradients, ADC)A pulse-sequence diagram is a timing chart with horizontal rows for the RF channel, the three gradient axes, and the ADC (signal readout).
- NMR pulse-acquire experiment: 90 degree pulse, FID, spectrumIn a pulse-acquire NMR experiment, a short radiofrequency pulse tips the net magnetization from the z axis into the transverse plane.
- Slice-selective excitation: sinc RF plus slice gradientIn MRI, a slice is chosen by applying a linear gradient along one axis so that resonance frequency varies with position, while a shaped radiofrequency (RF) pulse with a…
Intermediate level (18)
- Bloch equations: magnetisation vector over timeThe Bloch equations describe how the nuclear magnetisation vector M evolves under a static field, a radiofrequency pulse, and relaxation.
- Spin echo: dephasing and rephasingAfter a 90-degree pulse, spins in slightly different magnetic fields precess at different rates and lose phase coherence, so the signal decays with T2*.
- J-coupling: why peaks split (doublet, triplet, quartet)J-coupling is the through-bond interaction between neighbouring nuclear spins that splits one NMR resonance into a multiplet.
- 2D COSY: reading cross-peaks2D COSY (correlation spectroscopy) plots a 1H spectrum on both axes.
- k-space: sampling and image formationIn MRI, the raw data are samples of the spatial Fourier transform of the object's transverse magnetization, called k-space.
- Gradient encoding: slice, frequency, phaseMRI locates signal in space by adding small, linear magnetic field gradients to the main field B₀, so that the Larmor frequency and phase of spins depend on position.
- Gradient echo formationA gradient echo is formed when a magnetic field gradient first dephases transverse magnetization and then a gradient of opposite polarity rephases it, producing a…
- Inversion recovery and null pointInversion recovery starts with a 180-degree pulse that flips longitudinal magnetization to −M₀.
- T2* dephasing of isochromatsAfter an RF pulse tips magnetization into the transverse plane, the spins within a voxel precess at slightly different frequencies and fan out, so the net signal decays…
- Phase encoding line by lineIn MRI, phase encoding uses a brief gradient pulse to give spins different phases depending on their position along one axis.
- Ernst angle signal optimumThe Ernst angle is the flip angle that maximizes steady-state signal in a spoiled gradient-echo or repeated-pulse experiment when the repetition time TR is short…
- Diffusion weighting and b-valueDiffusion-weighted MRI makes the signal sensitive to random water motion by applying a pair of strong gradient pulses.
- Spin echo sequence: 90-180 pulses and isochromat rephasingA spin echo sequence uses a 90-degree excitation pulse followed by a 180-degree refocusing pulse to cancel dephasing caused by static field inhomogeneities.
- Gradient echo sequence and T2* decayA gradient echo sequence uses a low flip angle excitation and a reversal of a magnetic field gradient to refocus signal, without a 180 degree pulse.
- Inversion recovery sequence and the null pointAn inversion recovery sequence begins with a 180 degree pulse that flips longitudinal magnetization to the negative z axis.
- Cartesian k-space filling, one phase-encode line per TRIn conventional spin-warp MRI, k-space is filled one horizontal line per repetition time (TR).
- Fast (turbo) spin echo: echo train and k-space segmentsFast (turbo) spin echo acquires several phase-encoding lines per excitation by applying multiple 180-degree refocusing pulses and encoding each echo differently.
- CPMG echo train and T2 measurementThe CPMG sequence applies a 90 degree pulse followed by a train of 180 degree refocusing pulses, producing a series of spin echoes whose peak amplitudes decay with the…
Advanced level (10)
- Stimulated echo pathwaysA stimulated echo (STE) forms when three RF pulses act on spins: the first tips magnetization into the transverse plane, the second stores one component along z, and…
- Echo-planar k-space trajectoryEcho-planar imaging (EPI) fills all of k-space after a single RF excitation by rapidly oscillating the readout gradient while a small blipped phase-encode gradient…
- Spiral k-space samplingSpiral k-space sampling traverses k-space along an Archimedean or variable-density spiral, driven by time-varying gradients whose integral gives the k-space trajectory.
- Off-resonance and effective fieldWhen an RF pulse is applied at a frequency different from the Larmor frequency, spins in the rotating frame experience a residual z-field along with the B1 field.
- Echo-planar imaging: blipped phase encoding and the zigzag k-space pathEcho-planar imaging (EPI) fills all of k-space after a single RF excitation by rapidly oscillating the readout gradient and adding small phase-encode 'blips' between…
- Spiral k-space trajectoryA spiral k-space trajectory samples the spatial-frequency plane along a curve that winds outward from the center, driven by sinusoidal, amplitude-ramped gradient…
- Diffusion weighting: the Stejskal-Tanner pulsed-gradient spin echoThe Stejskal-Tanner pulsed-gradient spin echo (PGSE) sequence places two identical gradient pulses on either side of the 180-degree refocusing pulse.
- Spoiled gradient echo and the Ernst angle at steady stateA spoiled gradient echo (SPGR/FLASH) sequence repeats a low flip angle pulse every TR and destroys residual transverse magnetization each cycle, so only longitudinal…
- Balanced SSFP: steady-state magnetisation and bandingBalanced SSFP (bSSFP, TrueFISP/FIESTA/bFFE) uses a fast train of RF pulses with fully refocused gradients on all axes, so transverse magnetisation is preserved from one…
- COSY: the 90-t1-90-acquire sequence and where cross-peaks come fromCOSY is the simplest 2D NMR experiment: a 90° pulse, an evolution delay t1, a second 90° pulse, then acquisition during t2.