Content
Summary
After a 90-degree pulse, spins in slightly different magnetic fields precess at different rates and lose phase coherence, so the signal decays with T2*. A 180-degree pulse at time TE/2 flips the phases so that static field inhomogeneity effects reverse, and the spins refocus into an echo at time TE. The echo amplitude is reduced only by true T2 decay, which is irreversible.
Intuition
Picture runners on a circular track, each running at a slightly different constant speed. At the starting gun (the 90-degree pulse) they are together. They spread out, and the group's average position, the net signal, shrinks. Now at time tau a whistle makes everyone turn around and run back at the same speed as before. The fast runners are furthest ahead, but they now have the furthest to return, so all arrive back at the start at time 2tau together. This is the echo. Fixed differences in speed, caused by static field inhomogeneity or susceptibility, are undone. Random changes in speed, caused by molecular motion and spin-spin interactions, are not undone, so the echo is smaller than the original signal by exp(-TE/T2).
Key equations
Phase accumulated by spin i with frequency offset Delta omega_i after the 90-degree pulse.
The 180-degree pulse at t = tau inverts the phase sign.
Phase after the refocusing pulse; it is zero for every spin at t = 2 tau = TE.
Echo amplitude depends only on irreversible T2 decay.
The free decay rate combines true T2 relaxation with the dephasing from static field inhomogeneity.
Derivation
- Right after the 90-degree pulse all spins lie along one transverse direction, with phase zero.
- During 0 to tau, spin i gains phase Delta omega_i times t, where Delta omega_i is its offset from the reference frequency.
- At t = tau, a 180-degree pulse about an axis in the transverse plane reverses the sign of each phase: phi becomes minus Delta omega_i tau.
- After the pulse, spin i keeps precessing at the same Delta omega_i, so phi(t) = -Delta omega_i tau + Delta omega_i (t - tau).
- This simplifies to Delta omega_i (t - 2 tau), which is zero for all spins at t = 2 tau, independent of Delta omega_i.
- At that moment the spins are in phase and the signal peaks. Only random, time-varying field fluctuations remain uncorrected, giving the exp(-TE/T2) envelope.
Worked example
A tissue has T2 = 80 ms and T2* = 20 ms. A spin echo sequence uses TE = 60 ms. Compare the fraction of initial transverse signal remaining at TE for a spin echo and for a free induction decay.
- Spin echo: .
- exp(-0.75) is about 0.47.
- Free decay at 60 ms: .
- exp(-3) is about 0.05.
- Ratio: 0.47 / 0.05 is about 9.5.
Answer The spin echo retains about 47 percent of the signal, versus about 5 percent for free decay, roughly nine to ten times more.
Common mistakes
- Thinking the 180-degree pulse reverses the direction of precession; it flips the phases, and spins keep precessing the same way.
- Believing the echo recovers all signal; T2 losses from random fluctuations are not refocused.
- Confusing the echo time TE with the pulse spacing; the 180 pulse is at TE/2.
- Mixing up T2 and T2*; T2* is always shorter and includes static inhomogeneity.
- Assuming the refocusing works for spins that diffuse through varying fields; those lose phase irreversibly.