Content
Summary
Fast (turbo) spin echo acquires several phase-encoding lines per excitation by applying multiple 180-degree refocusing pulses and encoding each echo differently. The number of echoes per excitation is the echo train length (ETL), which divides the scan time by ETL. The ordering of echoes in k-space sets the effective TE and contrast, and T2 decay across the train causes blurring.
Intuition
In conventional spin echo, one excitation gives one echo and so one k-space line, and then we wait a full TR. That wastes time. In turbo spin echo, after one 90-degree pulse we fire a train of 180-degree pulses, each producing an echo. Before each echo we change the phase-encoding gradient, so every echo fills a different k-space line, and a rewinder gradient returns the phase afterwards. The echoes decay with T2, so later echoes are weaker. Lines acquired early are strong and those acquired late are weak. The echo placed near the k-space centre dominates contrast, so its time is the effective TE. Edges of k-space hold detail; if they are weak because of T2 decay, the image blurs. Fat also stays bright because rapid refocusing pulses reduce J-coupling modulation.
Key equations
Number of excitations (TR periods) needed to fill all phase-encoding lines.
Scan time is reduced by a factor equal to the echo train length.
Effective TE is the time of the echo that fills the central k-space line, the n_c-th echo with echo spacing ESP.
Signal amplitude of the n-th echo in the train, which weights k-space lines.
Derivation
- Conventional SE: one echo per TR, so time = TR × N_PE × NEX.
- In TSE, each excitation is followed by ETL refocusing pulses, each generating one echo.
- Each echo gets a different phase-encoding step, so one TR fills ETL lines.
- Shots needed = N_PE / ETL, so time = TR × (N_PE/ETL) × NEX.
- Echo n occurs at n × ESP and has amplitude set by e^(-n ESP/T2).
- Assigning the central line to echo n_c gives TE_eff = n_c × ESP.
- Segmenting k-space: each shot's echoes cover an interleaved or contiguous set of lines, so the amplitude modulation across k-space becomes a filter on the image, which causes blurring along phase-encode.
Worked example
A 2D TSE has 256 phase-encoding lines, TR = 4000 ms, NEX = 1, ETL = 16, echo spacing 10 ms. The central line is filled by echo 8. Find the scan time and the effective TE, and compare to conventional SE.
- Shots = 256/16 = 16.
- Scan time = 16 × 4000 ms = 64 s (per slice-set in the interleaved multislice acquisition).
- Conventional SE time = 256 × 4000 ms = 1024 s, about 17 min.
- TE_eff = 8 × 10 ms = 80 ms.
- Last echo at 16 × 10 = 160 ms; with T2 = 80 ms its signal is e^-2 ≈ 14% of the initial signal.
Answer Scan time is 64 s (16 times faster than 1024 s), with effective TE of 80 ms.
Common mistakes
- Thinking TSE shortens TR rather than reducing the number of TR periods.
- Treating TE_eff as the first echo time rather than the echo filling central k-space.
- Ignoring T2 blurring and SAR increase when ETL is long.
- Assuming all echoes in the train contribute equal signal.
- Confusing echo spacing with TE_eff.