Content
Summary
Echo-planar imaging (EPI) fills all of k-space after a single RF excitation by rapidly oscillating the readout gradient while a small blipped phase-encode gradient steps through ky. The result is a zigzag (blipped) trajectory that acquires a whole slice in tens of milliseconds, at the cost of sensitivity to off-resonance and T2* effects.
Intuition
Think of k-space as a sheet of graph paper, and the gradients as steering a pen. The pen position is the time integral of gradient area. A strong readout gradient Gx moves the pen horizontally along a line, collecting one row of data. Reversing Gx sends the pen back the other way, so every line is traversed in opposite direction to its neighbour. Between lines, a short phase-encode blip Gy nudges the pen up by one step in ky. Repeating this builds a serpentine path covering the whole sheet. Because everything happens during one T2* decay, later lines have less signal and accumulate phase errors from field inhomogeneity. Phase accumulates slowly along ky (long time between lines) so off-resonance appears mainly as distortion and shift along the phase-encode direction.
Key equations
Position along kx is the accumulated readout gradient area.
Position along ky is the accumulated blip area; each blip moves ky by Δky.
Blip area sets the phase-encode step and thus the field of view in y.
Off-resonance shift in the phase direction is frequency offset times the echo spacing, expressed in pixels, so it is large because the effective PE bandwidth is low.
Total readout duration is number of lines times echo spacing.
Derivation
- Start with the signal S(t)=∫ρ(x,y) exp(-i2π(kx x+ky y)) dx dy, where k is the gradient integral.
- After excitation, apply a pre-phasing lobe so the pen starts at (-kxmax, -kymax).
- Apply Gx of constant amplitude: kx increases linearly at rate γGx/2π, sampling one line at the ADC dwell time.
- At the line end, reverse Gx so kx decreases; at each reversal apply a Gy blip of area A giving Δky = γA/2π = 1/FOVy.
- Repeat Ny times, giving a serpentine path covering Ny lines.
- Because lines alternate direction, odd lines are time-reversed; reverse them before Fourier transform and correct phase mismatch between odd and even echoes (Nyquist ghost correction).
- Off-resonance Δf adds phase 2πΔf t; between neighbouring ky lines t differs by echo spacing, so the effective PE bandwidth per pixel is 1/(Ny·Δt_esp), giving a pixel shift of Δf·Ny·Δt_esp.
Worked example
A 64×64 single-shot EPI has echo spacing 0.5 ms. At 3 T, a region near an air cavity is off-resonance by 100 Hz. Find the acquisition time and the pixel shift in the phase direction.
- Acquisition time = 64 × 0.5 ms = 32 ms.
- Phase-encode bandwidth per pixel = 1/(Ny·Δt_esp) = 1/0.032 s = 31.25 Hz per pixel.
- Shift = 100 Hz / 31.25 Hz per pixel = 3.2 pixels.
- The readout direction bandwidth is much higher (tens of kHz), so the shift there is negligible.
Answer 32 ms acquisition; about 3.2 pixel displacement along the phase-encode direction.
Common mistakes
- Thinking each line needs a new excitation; in single-shot EPI there is only one RF pulse.
- Forgetting that alternate lines run in opposite directions and must be reversed before reconstruction.
- Assuming distortion occurs along the readout direction; it is mainly along phase encoding.
- Confusing blip area with amplitude: Δky depends on gradient area, not peak strength.
- Ignoring T2* decay across the echo train, which blurs the image along y.