Content
Summary
A stimulated echo (STE) forms when three RF pulses act on spins: the first tips magnetization into the transverse plane, the second stores one component along z, and the third recalls it. The STE appears at time tau1 + tau2 after pulse 3 (i.e., at t = 2*tau1 + tau2 from pulse 1... measured from pulse 1) with amplitude at most one half of the initial signal, but the storage interval relaxes with T1 rather than T2.
Intuition
Imagine spins fanning out in the transverse plane during the first interval tau1, each acquiring a phase set by its local frequency offset. The second pulse converts part of this phase-encoded pattern into a longitudinal magnetization grating: spins at different phases now hold different z values. During the mixing time TM this pattern sits along z, immune to T2 decay and dephasing, and only relaxes with T1. The third pulse flips the grating back into transverse magnetization, and spins whose phase was stored then rephase over a time tau1, giving an echo. Only about half of the signal is recovered because the other part of the pulse-2 output stays transverse and follows other pathways. This makes STE ideal for diffusion measurements with long diffusion times, for slow motion, and for tissues with short T2 but longer T1.
Key equations
The stimulated echo forms a time tau1 after the third pulse, mirroring the first evolution interval.
Amplitude of the stimulated echo for general flip angles; the factor is the maximum for -degree pulses, giving before relaxation.
Coherence pathway: transverse (-1), stored longitudinal (0), then refocused transverse (+1 reversing the sign of the phase accrued).
Diffusion attenuation in a stimulated echo gradient sequence, with Delta spanning tau1 + TM.
Derivation
- Start with equilibrium along . A pulse gives transverse magnetization .
- During , a spin with offset acquires phase , so .
- A second pulse rotates the component of along -like axis into : (one quadrature component, the other stays transverse).
- Write cos(phi) = (e^{i phi} + e^{-i phi})/2. The factor 1/2 is the origin of the half amplitude loss.
- During the pattern relaxes toward with ; the grating amplitude decays as . Transverse parts dephase and are removed by spoiling.
- The third pulse converts the grating back to transverse: .
- Over the next tau1 the phase evolves by +Omega*t. The term e^{-i phi} becomes e^{-i phi + i Omega t}, which equals 1 at t = tau1, forming the echo.
- The echo carries weighting of total (two intervals of transverse evolution) and weighting of , with amplitude .
Worked example
A 90-90-90 sequence has ms and ms in tissue with ms and ms. Compare the stimulated echo amplitude with a spin echo at ms (relative to ), and state when the STE forms after pulse 3.
- STE: S = 0.5 * exp(-2*10/50) * exp(-100/800).
- exp(-0.4) = 0.670; exp(-0.125) = 0.882.
- .
- Spin echo at TE = 20 ms: .
- Ratio STE/SE = 0.296/0.670 = 0.44.
- Echo time: the STE appears 10 ms after pulse 3, i.e. at t = 120 ms after pulse 1.
Answer STE amplitude is about 0.30 , about 44% of the spin echo (0.67 ), appearing 10 ms after the third pulse. The advantage is that the 100 ms storage costs only loss, far cheaper than loss over the same time (which would give ).
Common mistakes
- Claiming the STE has full amplitude; for ideal 90° pulses it is at most half of .
- Applying T2 decay over the whole tau1 + TM + tau1 period; only the two tau intervals decay with T2, and TM decays with T1.
- Forgetting that other echoes (primary echoes from pulse pairs, and the spin echo from pulses 2 and 3) also form and must be separated by timing or crusher/phase cycling.
- Not spoiling the leftover transverse magnetization during TM, which causes artifacts.
- Ignoring that tau1 sets the echo position after pulse 3, not TM.