Chemistry · Introductory

Absorbance and concentration

Written by SignalsLab

Early edition: these lessons are being reviewed.

Content

Summary

Absorbance measures how much light a solution absorbs at a given wavelength. The Beer-Lambert law says absorbance is directly proportional to concentration and path length, so a spectrophotometer reading can be used to find an unknown concentration.

Intuition

Imagine shining a flashlight through a glass of tea. A weak tea lets most light through, while a strong tea blocks more. Each dissolved molecule has a small chance of catching a photon, so doubling the number of molecules in the beam doubles the absorbing effect on a logarithmic scale. Absorbance is defined with a logarithm, so each equal layer of solution removes the same fraction of the remaining light, and this turns that multiplicative dimming into a straight-line relationship with concentration. A longer cuvette also puts more molecules in the beam, so path length matters in the same way.

Key equations

T=II0
(1)

Transmittance is the fraction of incident light that passes through the sample.

A=−log10⁡T=log10⁡I0I
(2)

Absorbance is the negative base-10 log of transmittance; it has no units.

A=εlc
(3)

Beer-Lambert law: absorbance equals molar absorptivity times path length times concentration.

c=Aεl
(4)

Rearranged form to find an unknown concentration.

Derivation

  1. Consider a thin slice of thickness dx. The light lost in it is proportional to the light arriving and the concentration: dI = -k c I dx.
  2. Rearrange: dI/I = -k c dx.
  3. Integrate from 0 to l, where intensity goes from I0 to I: ln⁡(I/I0)=−kcl.
  4. Convert to base 10: log10⁡(I0/I)=(k/2.303)cl.
  5. Define the molar absorptivity as ϵ=k/2.303 and A=log10⁡(I0/I), giving A=ϵlc.

Worked example

Problem

A dye solution in a 1.00 cm cuvette has absorbance 0.450 at 520 nm. The molar absorptivity at this wavelength is 15,000 L mol^-1 cm^-1. Find the concentration and the percent transmittance.

  1. Use c = A / (epsilon l).
  2. c = 0.450 / (15000 × 1.00) = 3.00 × 10^-5 mol/L.
  3. Transmittance T = 10^(-A) = 10^(-0.450) = 0.355.
  4. Percent transmittance = 0.355 × 100 = 35.5%.

Answer Concentration = 3.00 × 10^-5 M; transmittance about 35.5%.

Common mistakes

  • Confusing absorbance with transmittance: high absorbance means low transmittance.
  • Forgetting that absorbance is unitless, or leaving out the path length when it is not 1 cm.
  • Using the law at very high concentrations or absorbances above about 1 to 2, where the graph curves and readings are unreliable.
  • Not blanking the spectrophotometer with the pure solvent first.
  • Measuring at a wavelength different from the one at which epsilon was determined.

Animation

Animation coming soon

The animated version of this lesson is being prepared for the web. In the Signals AI app, lessons are drawn step by step.

Code

scene.py(89 lines)
import sys
import numpy as np
from manim import *
from blocks import *

# Beer-Lambert Law: A = epsilon * l * c
EPSILON = 2.5  # L/(mol*cm)
PATH_LENGTH = 1.0  # cm

def absorbance(c, eps=EPSILON, l=PATH_LENGTH):
    """Calculate Absorbance A from concentration c."""
    return eps * l * c

class Main(Scene):
    def construct(self):
        TitleCard(self, "Beer-Lambert Law", "Absorbance vs Concentration")
        
        # Equation
        eq = MathTex(r"A = \varepsilon \cdot l \cdot c", font_size=40)
        eq.to_edge(UP, buff=1.2)
        self.play(Write(eq), run_time=1.5)
        
        # Plot: A vs c
        # x_range: 0 to 4 M
        # y_range: 0 to 10 A
        plot = CurvePlot(
            lambda c: float(absorbance(c)),
            x_range=(0.0, 4.0, 1.0),
            y_range=(0.0, 10.0, 2.0),
            x_label="Concentration (M)",
            y_label="Absorbance (A)",
            color=C_MAIN,
            x_length=8.0,
            y_length=4.5
        )
        plot.move_to(ORIGIN)
        
        self.play(Create(plot.axes), FadeIn(plot.labels), run_time=1.5)
        self.play(Create(plot.curve), run_time=2)
        
        # Highlight key points
        # 1. c = 0, A = 0
        dot_zero = plot.dot_at(0.0, color=C_DIM)
        self.play(FadeIn(dot_zero), run_time=0.5)
        label_zero = Text("c=0, A=0", font_size=24, color=C_DIM)
        label_zero.next_to(dot_zero, DL, buff=0.1)
        self.play(FadeIn(label_zero), run_time=0.5)
        
        # 2. c = 2, A = 5
        c_mid = 2.0
        a_mid = absorbance(c_mid)
        dot_mid = plot.dot_at(c_mid, color=C_ACCENT)
        self.play(FadeIn(dot_mid), run_time=0.5)
        label_mid = Text(f"c={c_mid}, A={a_mid}", font_size=24, color=C_ACCENT)
        label_mid.next_to(dot_mid, UR, buff=0.1)
        self.play(FadeIn(label_mid), run_time=0.5)
        
        # 3. c = 4, A = 10
        c_high = 4.0
        a_high = absorbance(c_high)
        dot_high = plot.dot_at(c_high, color=C_GOOD)
        self.play(FadeIn(dot_high), run_time=0.5)
        label_high = Text(f"c={c_high}, A={a_high}", font_size=24, color=C_GOOD)
        label_high.next_to(dot_high, UR, buff=0.1)
        self.play(FadeIn(label_high), run_time=0.5)
        
        StepCaption(self, "Absorbance is directly proportional to concentration.")
        self.wait(1.5)


if __name__ == "__main__" and "--selftest" in sys.argv:
    # Test 1: At c=0, A should be 0
    assert abs(absorbance(0.0)) < 1e-9
    
    # Test 2: At c=2, A should be 5
    assert abs(absorbance(2.0) - 5.0) < 1e-9
    
    # Test 3: At c=4, A should be 10
    assert abs(absorbance(4.0) - 10.0) < 1e-9
    
    # Test 4: Linearity check
    c_vals = np.linspace(0, 4, 10)
    a_vals = np.array([absorbance(c) for c in c_vals])
    # Slope should be epsilon * l = 2.5, intercept should be 0
    slope, intercept = np.polyfit(c_vals, a_vals, 1)
    assert abs(slope - EPSILON * PATH_LENGTH) < 1e-9
    assert abs(intercept) < 1e-9
    
    print("selftest ok")

The Manim scene code that draws this lesson's animation in the Signals AI app (Python, Manim Community).

ccBYNC© 2026 SignalsLab. Lesson text shared as is under CC BY-NC 4.0.