Content
Summary
ELISA readouts (optical density) are related to analyte concentration by a sigmoidal dose-response curve, best described by the four-parameter logistic (4PL) model. We fit the 4PL to known standards, then invert it to calculate the concentration of unknown samples from their measured absorbance.
Intuition
At very low antigen concentration the signal sits at a floor (background). At very high concentration the binding sites saturate and the signal flattens at a ceiling. In between, signal rises steeply and roughly linearly on a log-concentration axis. A symmetric S-shaped curve on log scale captures this with four numbers: the bottom plateau, the top plateau, the midpoint concentration (EC50) where the signal is halfway, and a slope factor describing how sharply the curve rises. Once those four numbers are fitted to standards, we can read the curve backwards: measure an absorbance, get a concentration.
Key equations
4PL model: y is OD, x is concentration; a is the response at zero concentration (bottom), d is the response at infinite concentration (top), c is the EC50 (inflection point), b is the Hill slope.
Inverse 4PL used to back-calculate unknown concentration from measured OD y (valid for y strictly between a and d).
Nonlinear least squares used to fit parameters to the standards (often with weighting).
Derivation
- Start with a response that moves from a (at x=0) to d (at x large). Define the fraction of the span: (y-d)/(a-d).
- Model this fraction as a binding-like term: 1/(1+(x/c)^b). At x=0 it equals 1 (y=a); as x grows it tends to 0 (y=d); at x=c it equals 1/2.
- Hence y = d + (a-d)/(1+(x/c)^b).
- To invert, subtract d: y-d = (a-d)/(1+(x/c)^b).
- Rearrange: 1+(x/c)^b = (a-d)/(y-d).
- So (x/c)^b = (a-d)/(y-d) - 1 = (a-y)/(y-d).
- Take the 1/b power: x = c((a-y)/(y-d))^(1/b).
Worked example
A 4PL fit to standards gives a = 0.05, d = 2.05, c = 100 pg/mL, b = 1.5. A sample has OD = 1.05. Find its concentration.
- Compute a - y = 0.05 - 1.05 = -1.00.
- Compute y - d = 1.05 - 2.05 = -1.00.
- Ratio = (-1.00)/(-1.00) = 1.
- Raise to 1/b: 1^(1/1.5) = 1.
- x = c × 1 = 100 pg/mL.
- Check: 1.05 is the midpoint of 0.05 and 2.05, which is exactly the EC50 response, so the answer makes sense.
Answer 100 pg/mL (the EC50). Multiply by any dilution factor to get the original sample concentration.
Common mistakes
- Fitting a straight line to the whole range instead of the sigmoid, causing large errors near the plateaus.
- Reporting concentrations for ODs outside the range between a and d, or in the flat tails, where the inverse is extremely imprecise or undefined.
- Forgetting to multiply by the sample dilution factor.
- Mixing up a and d: here a is the zero-concentration response, which may be the lower or upper asymptote depending on assay format (competitive ELISAs decline).
- Not subtracting blank wells or using unweighted fitting when variance rises with signal.